Blown spuds, leaking wall gaskets, recalled pressure-assist tanks and running flush valves in a south Everett commercial building, worked through over five visits by Connor, Logan and Justin
Location: South Everett, WA
Service: Commercial toilet, urinal and flushometer repair
Technicians: Connor, Logan and Justin
Commercial restrooms run on flushometers, wall-hung bowls and pressure-assist tanks, not the household toilets most plumbers work on every day. Over the fall of 2025 our crew worked through the restrooms of a multi-story commercial building in south Everett one problem at a time: a bowl that blew its spud, a toilet leaking at the wall, a urinal leaking behind it, and three pressure-assist toilets under a manufacturer recall.
What We Found on the First Visit
In September, Logan and Justin went floor by floor. On a second-floor wall-hung toilet the spud, the fitting where the flushometer meets the bowl, blew out on the first flush. They installed a new spud and it blew out again, even tightened past the point where the rubber began to bulge, so they recommended a new bowl rather than a third try. Across the mezzanine, another wall-hung toilet held through fifteen flushes at the flushometer but was leaking at its wall gasket and needed a reset. Upstairs, a pressure-assist toilet needed its Sloan Flushmate tank rebuilt or replaced. They rebuilt the flushometer that needed it and cleared a clogged floor drain on the ground floor before they left.
What We Did Over the Next Three Months
In October, Connor and Logan hung a new 1.6 gallon wall-hung bowl on the second floor and rebuilt its flushometer with a new spud, spud gasket, escutcheon, neoprene wall gasket and tailpiece; two days later they came back with a longer tailpiece to suit the new bowl’s slightly different dimensions. A urinal in a second building on the site was leaking from a glue joint inside the wall, so they opened the wall, reamed out the old fitting and rebuilt the drain from there up to the urinal.
While they were there they wrote down the serial numbers of every Flushmate tank in the building and ordered the recall kits Sloan supplies for them. In November they installed the warranty parts on three toilets and tested every toilet for function and leaks, and cleaned and reset the top of a flushometer that had started to drip. One toilet ran nonstop afterward; its cartridge actuator had sheared off, separately from the recall repair, and the building contact was told. In December they replaced that cartridge to the manufacturer’s instructions, and rebuilt a ground-floor flushometer that ran constantly whenever its stop was open.
A Seized Flushometer on Evergreen Way
Not every flush valve can be rebuilt. In September 2026 Chase went to an office building along the Evergreen Way corridor for a toilet that would not flush right. The Sloan Royal flushometer was seized together and would not come apart, so he replaced the whole assembly with new Sloan parts, tightened every connection and flushed it five times to confirm good flow and no leaks.
Commercial Toilet Questions
Why does a commercial toilet keep running after it flushes?
Usually the flushometer’s inside parts have worn or caught debris, so the valve never closes. Rebuilding it with a new kit and adjusting the flush fixes most of them, as Connor and Logan did on a ground-floor toilet in south Everett. On a pressure-assist toilet, the same symptom often means a failed cartridge inside the tank.
Why does a wall-hung toilet leak where it meets the wall?
The neoprene gasket between the bowl and the wall fitting has failed or the bowl has shifted. The fix is to take the bowl off its carrier and reset it with a new gasket. On a second-floor toilet in south Everett the flushometer itself held through fifteen flushes; the leak was at the wall, and it needed a reset.
A flushometer is seized solid. Can it still be fixed?
Sometimes the inside parts can be replaced with the body left in place, but a valve corroded into one piece cannot be taken apart without damage. Then the whole assembly gets replaced, as Chase did on Evergreen Way in September 2026, and the new valve is flushed several times to prove flow and the connections.
Why It Matters for Building Owners
- Commercial fixtures are their own trade. Flushometers, carriers and pressure-assist tanks fail differently from household toilets.
- Recalls are worth checking. Recording the serial numbers on pressure-assist tanks is how the Sloan recall kits got ordered and installed.
- Repeat problems have a cause. That ground-floor drain kept clogging because the floor scrubber was emptied into it. Finding the cause is what stops the next call.
Our commercial plumbing page and our Everett commercial plumbing page cover the rest of our commercial work, and our toilet repair page covers household toilets.